Use the Modbus TCP server

Modbus logo

In this document, we will focus on the Modbus/TCP server.

Ned is permanently running a Modbus TCP Server that enables Ned to communicate with a PLC, or another computer in the same network.

The Modbus/TCP server is running on port 5020 by default. It has been built on top of the pymodbus library. This enables you to make Ned communicates with a PLC, or another computer on the same network.

Introduction

All 4 Modbus datastores are implemented: Coils, Discrete inputs, Holding registers, Input registers. Each datastore has a different set of functionalities. Note that each datastore contains a completely different set of data.

Discrete Input and Input register are READ-ONLY tables. Those have been used to keep the robot state.

Coil and Holding Register are READ/WRITE tables. Those have been used to give user commands to the robot. Hence, those 2 tables do not contain the robot state, but the last given command.

Address tables start at 0.

Coils

Each address contains a 1bit value.

READ/WRITE (the stored values correspond to the last given command, not the current robot state)

Accepted Modbus functions:

  • 0x01: READ_COILS
  • 0x05: WRITE_SINGLE_COIL

This datastore can be used to set Digital I/O mode and state. Digital I/O numbers used for Modbus:

Digital IO addresses offset table
Address offset Niryo One / Ned digital IO Ned2 digital IO
0 1A DI1
1 1B DI2
2 1C DI3
3 2A DI4
4 2B DI5
5 2C D01
6 SW1 D02
7 SW2 D03
8   D04
Address Description
0-8 Digital I/O mode (Input = 1, Output = 0)
100-108 Digital I/O state (High = 1, Low = 0)
200-299 Can be used to store your own variables

Discrete inputs

Each address contains a 1bit value.

READ-ONLY

Accepted Modbus functions:

  • 0x02: READ_DISCRETE_INPUTS

This datastore can be used to read Digital I/O mode and state. See the Coils section above for digital I/O number mapping.

Address Description
0-8 Digital I/O mode (Input = 1, Output = 0)
100-108 Digital I/O state (High = 1, Low = 0)

Holding registers

Each address contains a 16bit value.

READ/WRITE (the stored values correspond to the last given command, not the current robot state)

Accepted Modbus functions:

  • 0x03: READ_HOLDING_REGISTERS
  • 0x06: WRITE_SINGLE_REGISTER
Address Description
0-5 Joints (mrad)
10-12 Position x,y,z (mm)
13-15 Orientation roll, pitch, yaw (mrad)
100 Sends Joint Move command with stored joints
101 Sends Pose Move command with stored position and orientation
102 Sends Linear Pose Move command with stored position and orientation
110 Stops current command execution
150 Is executing command flag
151 Last command result*
152 Last command data result (if not vision related)
153 - 158 Vision - Target pose result
159 Vision - Shape of the object found (-1: ANY, 1: CIRCLE, 2: SQUARE, 3: TRIANGLE, 0: NONE)
160 Vision - Color of the object found (-1: ANY, 1: BLUE, 2: RED, 3: GREEN, 0: NONE)
200-299 Can be used to store your own variables
300 Learning Mode (On = 1, Off = 0)
301 Joystick Enabled (On = 1, Off = 0)
310 Requests new calibration
311 Starts auto calibration
312 Starts manual calibration
401 Gripper open speed (100-1000)
402 Gripper close speed (100-1000)
500 Updates the tool id according to the gripper plugged (gripper 1: 11, gripper 2: 12, gripper 3: 13, vaccum pump: 31)
501 Stores the tool id
510 Opens gripper previously updated
511 Closes gripper previously updated
512 Pulls air vacuum pump with id 31
513 Pushes air vacuum pump with id 31
520 Updates the conveyor id and enable it
521 Detaches or disables the conveyor previously enabled and updated
522 Starts the conveyor previously enabled and updated
523 Sets the conveyor direction (backward = number_to_raw_data(-1), forward = 1)
524 Sets the conveyor speed (0-100)(%)
525 Stores the conveyor id
526 Stops conveyor previously enabled and updated
600 TCP - Enables or disables the TCP function (Tool Center Point).
601 Activates the TCP function (Tool Center Point) and defines the transformation between the tool_link frame and the TCP frame.
610 Vision - Gets target pose from relative pose, with stored relative pose and height_offset
611 Vision - Gets target pose from camera, with stored workspace name, height offset, shape and color
612 Vision - Vision pick, with stored workspace name, height offset, shape and color
613 Vision - Moves to object, with stored workspace name, height offset, shape and color
614 Vision - Detects object, with stored workspace name, shape and color
620 Vision - Stores workspace’s height offset
621 Vision - Stores relative pose x_rel
622 Vision - Stores relative pose y_rel
623 Vision - Stores relative pose yaw_rel
624 Vision - Stores requested shape (-1: ANY, 1: CIRCLE, 2: SQUARE, 3: TRIANGLE)
625 Vision - Stores requested color (-1: ANY, 1: BLUE, 2: RED, 3: GREEN)
626 - max 641 Vision - Stores workspace’s name, as a string encoded in 16 bits hex (see examples on how to store a workspace name from a client)
650 Set Analog IO - Arg: [Analog IO number, voltage 0V- 5000mV]

‘*’ The “Last command result” gives you more information about the last executed command:

  • 0: no result yet
  • 1: success
  • 2: command was rejected (invalid params, …)
  • 3: command was aborted
  • 4: command was canceled
  • 5: command had an unexpected error
  • 6: command timeout
  • 7: internal error

Input registers

Each address contains a 16bit value.

READ-ONLY.

Accepted Modbus functions:

  • 0x04: READ_INPUT_REGISTERS
Address Description
0-5 Joints (mrad)
10-12 Position x,y,z (mm)
13-15 Orientation roll, pitch, yaw (mrad)
200 Selected tool ID (0 for no tool)
300 Learning Mode activated
400 Motors connection up (Ok = 1, Not ok = 0)
401 Calibration needed flag
402 Calibration in progress flag
403 Raspberry Pi temperature
404 Raspberry Pi available disk size
405 Raspberry Pi ROS log size
406 Ned RPI image version n.1
407 Ned RPI image version n.2
408 Ned RPI image version n.3
409 Hardware version (1 or 2)
530 Conveyor 1 connection state (Connected = 1 , Not connected = 0)
531 Conveyor 1 control status ( On = 0, Off = 1)
532 Conveyor 1 Speed (0-100 (%))
533 Conveyor 1 direction (Backward = -1, Forward = 1)
540 Conveyor 2 connection state (Connected = 1 , Not connected = 0)
541 Conveyor 2 control status ( On = 0, Off = 1)
542 Conveyor 2 Speed (0-100 (%))
543 Conveyor 2 direction (Backward = -1, Forward = 1)
600 - 604 Analog IO mode
610 - 614 Analog IO state in mV
Analog IO addresses offset table
Address offset Niryo One / Ned analog IO Ned2 analog IO
0 / AI1
1 / AI2
2 / AO1
3 / AO2